SOLUTION
Recommend
Contact US
TEL86 136 1622 3382
hotline800-9993-818
addressNo. 1888, Zhonghuayuan West Road, Kunshan City, Jiangsu Province, 22/F, Taohuayuan Science and Technology Innovation Park, Furong East Road, Songgang, Bao'an District, Shenzhen, China
Feed testing HOME >> SOLUTION >> Feed testing
Application of High Performance Liquid Chromatography (LC) in Feed Industry
1. Detection of VE and VD3
2. Detection of VA
3, the detection of VK3
4, VB6 detection
5. Detection of VB12
6. Detection of niacin and folic acid
7. Detection of pantothenic acid
8, the detection of immunoglobulin IgG
9. Detection of methionine hydroxy analogues
10. Detection of olaquindox
11. Detection of furazolidone, furaltadone, and nitrofurazone
12. Detection of ractopamine
13. Detection of oxytetracycline
14, the detection of chlortetracycline
15. Detection of Sulfaquinoxaline
16. Detection of phenobarbital
17. Detection of clopidol
18. Detection of Lockhart
19, detection of malachite green
20. Detection of clenbuterol and salbutamol
21, the detection of melamine
22. Detection of Sudan Red
23. Detection of benzo(a) pyrene
24. Detection of Furazolidone
25. Detection of bacitracin zinc
26, the detection of monensin
27. Detection of biogenic amines
28, the detection of ricinine
29. Detection of lutein
30. Detection of virginiamycin
31. Detection of hypnotic ketone
32. Determination of Norfloxacin
33. Detection of Cimatero
34. Detection of dimetridazole
35. Detection of diazepam
36. Detection of estradiol
37. Detection of chlorophenylhydrazine hydrochloride
38. Detection of Lassaloc Sodium
39. Detection of Ammonium Hydrochloride
40. Detection of nicarbazin
41. Detection of sulfonamides
42. Detection of dopamine hydrochloride
43. Trimethoprim detection
44. Detection of ampicillin
45. Detection of Acidifiers Citric Acid, Fumaric Acid and Lactic Acid
46. Detection of L-ascorbic acid-2-phosphate
47. Detection of tilmicosin
48. Detection of dinitramide
49. Detection of Nadolol
50, 5 kinds of glucocorticoid testing
51, clomiphene detection
52. Detection of Anastrozole
53. Detection of raloxifene
54. Detection of Apramycin
56. Detection of nitrofurans
57. Detection of chlorenoestrol drugs
Atomic Absorption Solutions in the Feed Industry
1. Determination of lead (Pb) elements
2. Determination of Cadmium (Cd) Elements
3, Determination of chromium (Cr) elements
4. Determination of copper, iron, manganese, zinc, sodium, potassium, calcium and magnesium
Atomic Fluorescence Solutions in the Feed Industry
1. Detection of arsenic in feed
2. Determination of selenium in feed
3, the detection of mercury in feed
4, tin detection
Detailed solution please consult 400-7102-888,800-9993-800
Skyray Analytical Testing Instrument Research Institute has three centers, namely "analysis instrument research and development center", "physiochemical analysis and testing center" and "analysis and testing technology application development center."Tianrui Analytical Instruments Co., Ltd. recently formed a staff of 1 academician, 11 Ph.D., 13 senior engineers, 17 masters, and 50 undergraduate R&D personnel from famous universities.
Mr. Liu Zhaogui: graduate student in nuclear physics from Tsinghua University. It has been appraised as the outstanding entrepreneur of Jiangsu Province, the young and middle-aged experts who have outstanding contribution in Jiangsu Province, the first science and Technology Minister of Kunshan, and the national science and technology ministry "scientific and technological innovation and entrepreneurial talent". With the approval of the State Council, the special allowance of the State Council is enjoyed.
Dr. Yao graduated from the Department of Engineering Physics of Tsinghua University with a Ph.D. in nuclear electronics. He has been engaged in the development of analytical instruments for 26 years. He is mainly engaged in the research of X-ray fluorescence analysis technology and application technology, and he participated in the "Thirteenth Five-Year Plan" national key instrument technology research and development. Patent of "Spectrometer Grating 2D" patent, "X-ray fluorescence double crystal fixed element track spectrometer" patent and "X-ray fluorescence spectrum analyzer pyrolytic graphite crystal beam splitter" patent, and participated in the drafting of a number of national standards industry The standard is an authoritative expert in the X-ray fluorescence spectrometer industry in China.
The FP (Basic Parameters) algorithm is an effective method for X-ray fluorescence spectrometry analysis. It can perform qualitative and quantitative analysis of the elemental components of the sample with little or no standard sample, and can also analyze the thickness of the coating or coating.It is well known that the biggest problem with X-ray fluorescence analysis is that elemental fluorescence intensity is affected by coexisting elements (matrix absorption and enhancement effects) and is not usually linear with content. The basic parameter method has already taken into account the matrix effect in the calculation of the spectrum, and the linear relationship between the calculated content and the known content can be obtained. Using a few known sample calibration algorithms to eliminate systematic errors can achieve accurate quantitative results.
The polarization secondary target excitation technology can remove the scattering background to the maximum extent, improve the signal to noise ratio, and reduce the detection limit of the detector. Assuming that the x-ray generated by the anode of the x-ray tube is non-polarized and is incident on the target (scattering body) in the z-axis direction, the scattered beam propagating along the y-axis is linearly polarized light. The electric field vector vibrates in the v plane and the vibration direction is parallel to the X axis. The sample placed on the y-axis is excited by polarized light, producing unpolarized fluorescent x-rays. Since the sample and the sample support do not generate scattered radiation in the X-axis direction, placing the detector on the x-axis can fully utilize the polarization effect and reduce the background caused by the elastic and inelastic scattering of x-rays.
From the X-ray generator to the sample, the X-ray fluorescence emitted by the sample to the detector is called the light path. The shorter the distance traveled by the optical path is, the less interference will be caused. Skyray Instrument designed an ultra-short optical path technology to ensure the accuracy of light element detection results, and is particularly suitable for RoHS-compliant halogen-free instruction detection.
The micro-level positioning, micro-scanning analysis, the point-to-point centering of the spatial micro-sized spot and the determination of the spatial micro-focus spot position have been truly achieved. A translation and rotation switching position device realizes position rotation switching in a small space, avoids the large space required for the linear motion and the common rotation movement, because the problem of lengthening of the optical path caused by the inability to fit is eliminated.
XRF test and analysis instruments are generally used for the comparison test of standard samples, which are subject to the quality of the standard samples during the test. Tianrui Instrument's original non-standard technology can carry out all-element analysis without standard samples, leading the development trend and trend of the industry.
XRF test and analysis instruments are generally used for the comparison test of standard samples, which are subject to the quality of the standard samples during the test. Tianrui Instrument's original non-standard technology can carry out all-element analysis without standard samples, leading the development trend and trend of the industry.
Skyray's unique SNR enhancement technology can effectively remove noise signal interference and minimize element detection limits.
As shown in Figure SUPER XRF 1050, the determination of Pb in food can be as low as 0.59 ppm.
patented intelligent analysis software enables precise analysis of 80 elements, non-standard quantitative analysis, micro-analysis, thin film analysis, and advanced sub-spectral analysis.
hotline:800-9993-818
TEL:86 136 1622 3382
Address: 1888 Zhonghuayuan West Road, Kunshan City, Jiangsu Province/
深圳宝安区松岗芙蓉东路桃花源科技创新园22层